LCA6000,dz¼Ó°è,dz·®°è,lca6000,Air Velocity Meter,Volume Flow Meter,ÈÞ´ë¿ë dz¼Ó°è,ÈÞ´ë¿ë dz·®°è,Air Flow,dz¼Ó ÃøÁ¤,dz·® ÃøÁ¤">

 ÀÀ¿ë ±â°èº°(¹°)

 ÀÀ¿ë ±â°èº°(°ø±â)

 ±â»ó °üÃøÀåÄ¡

 ±âŸ °üÃøÀåÄ¡

 Á¦ÀÛ ½ÇÇèÀåÄ¡

 

 

 

  ÇöÀçÀ§Ä¡ : HOME > Á¦Ç°Á¤º¸ > ÀÀ¿ë ±â°èº° > dz¼Ó/dz·® ÃøÁ¤ ÀåÄ¡ > LCA6000

 

          LCA6000 (The LCA range of Anemometers)

 

  Choice of direct velocity or volume flow in m/sec, ft/min,

    m©ø/sec and ft©ø/min.

 

  Clear digital display.

 

  Fast response with superb accuracy.

 

  Instrinically safe unit available.

 

 

 

 

 

 

 

 

  JUST HAND IT TO AIRFLOW

 

  The LCA range of hand held rotating vane anemometers offers a superb choice of models

     featuring automatic averaging of air velocity through to direct readings of volume flow rate,

     even in hazardous areas.

 

  All models have an integral Metric/Imperial display selector switch as standard.

 

  The LCA6000 has a single push-button control in the hand-grip. When this button is

     pressed and held down, the instrument averages the air velocity over 3 seconds (Metric

     display) or 6 seconds (Imperial display). The air velocity is displayed digitally and the

     reading is held as long as the button remains depressed.

 

  The LCA6000VT, LCA6000RVT, LCA6000VA and LCA30iS average approximately every

     3 seconds and can be used over a variable time base up to 12 minutes duration.

 

  The LCA6000RVT is specially calibrated in reverse so that the digital display faces the

     operator during monitoring of fume cupboards and laminar flow cabinets. It is also

     supplied with a certificate of calibration with plotted results for velocities up to 5m/sec

     ensuring a higher degree of accuracy for these low velocity extract situations.

 

  The LCA6000VA and LCA30iS have the facility to input the area of the duct or grille to be

     monitored and to give the resulting reading as volume flow in cfm,(cubic feet per minute)

     or m©øsec, (cubic metres per second). The area is easily changed for each new

     application.

 

  All versions are robust and reliable and can be used with one hand. The lightweight casing

    is aerodynamically designed in high impact ABS.

 

  An extremely helpful option is the AIRCONE kit. An inexpensive kit containing a circular and

    rectangular moulded hood for air balancing which simply clips onto the vane probe to

    provide direct air volume flow readings from grilles, linears and diffusers.

 

  Calibrated to an Internationally recognised standard the LCA is supplied with a FREE

    TRACEABLE CERTIFICATE OF CALIBRATION and a reply card is also included for

    purchasers to register with our FREE annual calibration reminder service.

 

  All AirflowTM instruments, including the LCA, are designed to help meet the stringent

    requirements of the Control Of Substances Hazardous to Health (COSHH) and Building

    Regulations in the UK.

 

  For our UK customers the reminder card service ensures valid certification for COSHH,

    ISO9001 and Quality Assurance requirements.

 

 

 

 

 

 LCA6000

Parameter Metric Mode Imperial Mode

  Information common to all LCA anemometers

Operating Environment Barometric Pressure: 500 mbar to 2 bar
Temperature: -10¡ÆC to 50¡ÆC
Barometric Pressure: 15 in Hg to 60 in Hg
Temperature: 14¡ÆF to 122¡ÆF
Velocity Resolution 0.01 m/sec 1 ft/min
Overall Dimensions
Instrument only
268mm ¡¿ 113mm ¡¿ 43mm deep 10.55 in ¡¿ 4.44 in ¡¿ 1.69 in deep
Weight
less batteries
260g 0.62 lb
Power Supply 1 only 9v battery type PP3 or equivalent IEC ref 6F22 standard, alkaline or rechargable
Note: Zinc Carbon only for use of iS version in hazardous areas
Battery Life 50 hours continuous life (alkaline batteries)

  Items specific to LCA6000

Velocity range 0.25 to 30 m/sec 50 to 6000 ft/min
Accuracy at 20¡ÆC and 1013 mbar

0.25 to 4.99 m/sec ¡¾0.1 m/sec

5 to 30 m/sec calibrated better than ¡¾2% of reading

50 to 999 ft/min¡¾20 ft/min

1000 to 6000 ft/min calibrated better than ¡¾2% of reading

  Items specific to LCA6000VT, LCA6000RVT, LCA6000VA and LCA30iS

Velocity range 0.25 to 30 m/sec 50 to 6000 ft/min
Maximum averaging time 12 minutes
Accuracy at 20¡ÆC and 1013 mbar Calibrated better than ¡¾1% of reading ¡¾1 digit

  Items specific to LCA6000VA and LCA30iS

Volume range displayable 0.002 to 3000 m©ø/sec 4 to 999999 cfm
Area input range 0.008 to 90 m©÷ 0.08 to 900 ft©÷

 

 

HOME | ȸ»ç¼Ò°³ | Á¦Ç°¼Ò°³ | °í°´Áö¿ø | °ü·ÃÁ¤º¸ | ¿Â¶óÀΰßÀû

  °æ±âµµ ¼º³²½Ã ºÐ´ç±¸ ±¸¹Ìµ¿ 165¹øÁö Æ÷½ººô 523È£

  ¹®ÀÇ ÀüÈ­ (031) 782 - 9165/6     Æѽº (031) 782 - 9167

  Copyright (c) 2006 C & V Corporation All Rights Reserved